Biocompatibility — ISO 10993
Cytotoxicity, irritation, sensitization, systemic toxicity, implantation and chemical characterization, with a documented biological evaluation plan and report aligned to ISO 10993-1:2025.
Explore biocompatibilityMedical device testing · Southeast Asia
Biocompatibility, electrical safety, EMC, sterilization and packaging validation from one ISO/IEC 17025-accredited laboratory — reported in CSDT format for HSA, MDA, Thai FDA, BPOM, Vietnam MOH and Philippines FDA submissions.
Standard Group is a Chinese third-party testing organisation that runs one of the larger medical device laboratories in Asia. For Southeast Asian manufacturers and importers, we test devices to ISO 10993, IEC 60601-1/-1-2, ISO 11135/11137/11607 and ISO 10993-18, and issue English reports structured for ASEAN CSDT dossiers. Reports are issued under CNAS and A2LA ISO/IEC 17025 accreditation, with GLP for preclinical work.
01 · What we test
Cytotoxicity, irritation, sensitization, systemic toxicity, implantation and chemical characterization, with a documented biological evaluation plan and report aligned to ISO 10993-1:2025.
Explore biocompatibilityIEC 60601-1 safety testing, IEC 60601-1-2 electromagnetic compatibility, collateral standards, environmental and usability evaluation for active devices.
Explore safety & EMCEO, radiation, moist heat and VHP validation, plus sterile barrier packaging to ISO 11607 and shelf-life studies that hold up to regulator questions.
Explore validationMaterial composition, extractables and leachables screens with Q-TOF and GC-MS, toxicological risk assessment, and documentation of clinical-use extraction conditions.
Explore characterizationGLP large-animal and implantation models, functional and safety endpoints, and histopathology — the in vivo layer that Class C and D submissions usually demand.
Explore preclinicalTest reports structured for ASEAN CSDT, EU MDR technical documentation and FDA 510(k) summaries, with gaps flagged before you submit rather than after.
Explore registration02 · Why SEA teams work with us
A device that needs biocompatibility, sterilization validation and packaging testing often ends up split across three vendors in three countries — and the regulator sees three incompatible report formats. We keep the chain in one quality system.
03 · Market requirements
| Market | Authority | Classes | Route | Test evidence typically reviewed |
|---|---|---|---|---|
| Singapore | HSA | ABCD | Class A exempt from registration; B–D via PRISM, with immediate / expedited / full routes | CSDT dossier, biocompatibility, sterilization validation for sterile devices, software V&V and cybersecurity for connected devices |
| Malaysia | MDA | ABCD | Registered via local authorised representative; conformity assessment route by class | Full technical file, biological evaluation, EMC and safety reports, sterilization and packaging validation for sterile devices |
| Thailand | Thai FDA | 1234 | Licensed importer required; CSDT accepted for Classes 2–4 | Test reports from accredited labs, biological evaluation, sterilization validation, labels and IFU in Thai |
| Indonesia | MoH / BPOM | ABCD | AKL registration through a local distributor; independent Indonesian review regardless of CE or FDA status | Own-format dossier with test reports, biocompatibility, sterilization and packaging evidence, plus local labelling |
| Vietnam | MOH (DMEV) | ABCD | Class A/B filed at provincial level, C/D at MOH; broad recognition of reference-agency approvals | Classification document, accredited test reports, ISO 13485, and reference approvals where relied on |
| Philippines | FDA (CDRRHR) | ABCD | Notification (A/B) and registration (C/D) via eServices; CSDT preferred under current circulars | CSDT-based technical documentation, biological evaluation, safety/EMC and sterilization evidence |
Sources: HSA regulatory overview and Class B registration guides; ASEAN AMDD/CSDT implementation summaries. Requirements change — treat this as a planning table, not legal advice.
04 · How a project runs
Device classification, intended use, materials and existing reports. We tell you what can be reused and what cannot.
Standards, methods, sample sizes, acceptance criteria and a delivery date per report, in one document.
Shipping instructions, receipt inspection, testing with deviation notices raised early rather than at report stage.
Signed English reports with raw data, mapped to CSDT sections, plus a reviewer-ready summary you can hand to your agent.
05 · Questions we get weekly
Yes, if the report comes from an ISO/IEC 17025-accredited laboratory with the relevant method in scope and contains enough detail for review. HSA and MDA accept data from accredited laboratories outside their jurisdictions; reviewers look at accreditation scope, method, raw data and traceability, not the country of the lab. Our medical device reports are issued under CNAS and A2LA ISO/IEC 17025 accreditation, in CSDT structure.
A typical ISO 10993-1 battery for an externally communicating device — cytotoxicity, irritation, sensitization plus chemical characterization — runs about 6 to 10 weeks from sample receipt. Implantation, chronic toxicity or reproductive studies extend that. Dates are fixed in the test plan before shipping.
We supply the technical content: biological evaluation reports, preclinical summaries, sterilization and packaging validation, chemical characterization and safety/EMC reports, each mapped to CSDT sections. Full dossier assembly, local authorised representative and authority liaison are delivered together with our regulatory partners in each ASEAN market.
With a pre-agreed logistics plan: shipping instruction sheet, commercial invoice template, customs classification, temperature control where the device or extracts require it, and chain-of-custody on arrival. Most SEA capitals reach us in three to five days by air freight.
Class A to D: active devices, sterile devices, implants, IVDs, dental and orthopaedic products, software-enabled devices. Low-risk Class A devices usually need only a subset of testing; Class C and D implants typically need chemical characterization, implantation studies and full sterilization validation.
Next step
Tell us the device, intended use, target markets and submission date. We reply with a standards list, sample quantities, dates and a fixed price.