Market access · United States

FDA 510(k) test data, prepared the way reviewers read it.

Substantial equivalence rests on evidence: performance testing against a predicate, biocompatibility, safety and EMC, sterilization and packaging, and software documentation. We produce that evidence in a report format FDA reviewers can follow without asking for the protocol.

510(k) / De Novo supportFDA-recognised standards90 FDA-day review goalQMSR-aware documentation
In short

A 510(k) is a comparison, not a proof of novelty. The test data has to show your device performs like the predicate on the endpoints FDA recognises — and that differences do not raise new safety or effectiveness questions. Foreign laboratories can supply that data; the usual failure is reporting that omits protocols, acceptance criteria or raw results.

What goes in the file

The evidence a reviewer expects.

FDA reviews to recognised consensus standards. Naming the standard, the edition and the clause in the report is not bureaucracy — it is what lets a reviewer tick the box without writing back.
Typical 510(k) test evidence by device type
Evidence areaTypical requirementReport content we supply
BiocompatibilityISO 10993-1 evaluation consistent with FDA guidance; endpoints by contact category and durationBiological evaluation report with test data, extractables data and toxicological assessment
Electrical safetyIEC 60601-1 and applicable collateral standardsClause-by-clause safety report with abnormal-condition results
EMCIEC 60601-1-2, essential performance definedEmissions and immunity report, setup descriptions, pass/fail matrix
SterilizationFDA-recognised sterilization standards; SAL 10^-6; residualsValidation report, bioburden, cycle data, residuals results
Packaging & shelf lifeISO 11607 series, ageing and distribution testingSeal integrity, ageing and transport reports
SoftwareIEC 62304 lifecycle evidence, cybersecurity documentationSoftware V&V summary and cybersecurity file aligned to FDA expectations
Performance / benchDevice-specific FDA-recognised standards or predicate-based protocolsProtocol, sample size justification, results tables, statistical analysis

Sequencing & reuse

Test once against the strictest reader.

If you are filing in the US and ASEAN, the report set overlaps heavily. Sequencing the work to the FDA-recognised standard versions usually means the same data can be reused for HSA or MDA without a second campaign.

  • Predicate first. Choose the predicate before writing the protocol — the performance endpoints come from the comparison, not the catalogue.
  • Recognised standards register. Confirm each standard's recognition status and edition before the test window, not after the report is signed.
  • Gap review, not restart. Existing CE data is often reusable; we compare it against FDA guidance and list only the real gaps.
  • QMSR context. Since February 2026 the US quality system regulation aligns with ISO 13485, so documentation control and risk-based review expectations now look familiar to EU-audited manufacturers.
What we do not do: prepare or file the 510(k) submission itself, hold the US agent appointment, or provide regulatory determination on classification. We supply test data and technical documentation; the submission is filed by you or your regulatory consultant.
Active medical device undergoing EMC testing in an anechoic chamber
ESSENTIAL PERFORMANCE · 60601-1-2

FAQ

510(k) questions.

Can foreign test data be used in a 510(k)?

Yes. FDA does not require US-based testing and accepts data from accredited laboratories abroad when methods follow recognised standards and the report includes protocol, raw data, acceptance criteria and conclusions. Location is rarely the objection; incomplete reporting is.

How long does the review take?

FDA's goal is a decision within 90 FDA days of a complete submission and most clear inside that window. The real critical path is usually the testing calendar before filing.

What is QMSR and does it change our reports?

The Quality Management System Regulation aligned 21 CFR 820 with ISO 13485 and took effect in February 2026. Test methods do not change; documentation control and risk-based review expectations do, and our reports are structured accordingly.

Do we need to repeat biocompatibility testing done for CE?

Usually not, if the testing followed FDA-recognised ISO 10993 editions and the device, materials and sterilization are unchanged. We review the existing report against FDA's expectations and identify gaps instead of restarting the programme.

Next step

Tell us the predicate and the device differences.

We return the performance and safety evidence needed to support substantial equivalence.

Request a 510(k) evidence plan standard@sitande.com Replies within one working day · English