Chemical, physical & biological properties
ISO 10993 biological evaluation, chemical characterization, toxicological risk assessment, residues and degradants.
Biocompatibility evidenceMarket access · European Union
Under MDR 2017/745 a notified body reviews the technical documentation line by line. We generate the test evidence that Annex II expects, mapped to GSPRs, with the deviations and open questions stated openly rather than buried.
CE marking under MDR requires general safety and performance requirements to be met with documented evidence: biological evaluation, electrical safety and EMC, sterilization and packaging validation, software and usability files, plus a clinical evaluation report. The test data is only part of the file — the stronger constraint is whether each GSPR can be traced to a specific report, clause and result.
What the file needs
ISO 10993 biological evaluation, chemical characterization, toxicological risk assessment, residues and degradants.
Biocompatibility evidenceSterilization validation, bioburden, residuals, reprocessing validation and packaging integrity for sterile devices.
Validation evidenceIEC 60601-1 safety, IEC 60601-1-2 EMC, mechanical and environmental testing to harmonised standards.
Safety & EMC evidenceSoftware V&V to IEC 62304, usability to IEC 62366-1, cybersecurity documentation to IEC 81001-5-1.
Software evidenceInputs for the clinical evaluation report: literature strategy review, equivalence justification gaps, PMCF test endpoints.
Clinical inputsA gap memo against the Annex II structure before the file goes to the notified body, including standard-version currency.
Pre-submission reviewOne test programme, several markets
If you are pursuing both CE and Southeast Asian registrations, the underlying reports are largely the same — only the dossier structure, language and reference approvals change. Sequencing the testing for the stricter file first usually removes duplication.
FAQ
It helps, it does not replace. Some authorities use reference-agency approvals to expedite review and Vietnam recognises a broad set, but each market still needs its own registration, local representative and often its own labelling.
The standards largely carried over; the documentation burden did not. MDR adds a fuller GSPR mapping, a clinical evaluation report with a defined literature strategy, PMS and PMCF plans, UDI and, for higher classes, a summary of safety and clinical performance.
Reports must reflect the state of the art, which in practice means the harmonised standards in force. Older editions are generally accepted only with a written gap assessment showing the differences do not affect safety.
No. We provide test and evaluation evidence and answer the notified body's technical questions. The authorised representative and notified body are separate appointments held by other parties.
Next step
Send the device class, standards claimed and target dates. We map one test programme to both files.