Under MDR 2017/745 a notified body reviews the technical documentation line by line. We generate the test evidence that Annex II expects, mapped to GSPRs, with the deviations and open questions stated openly rather than buried.

MDR 2017/745Annex II documentationGSPR mappingNotified body Q&A support
In short

CE marking under MDR requires general safety and performance requirements to be met with documented evidence: biological evaluation, electrical safety and EMC, sterilization and packaging validation, software and usability files, plus a clinical evaluation report. The test data is only part of the file — the stronger constraint is whether each GSPR can be traced to a specific report, clause and result.

What the file needs

Evidence mapped to GSPRs, not stacked in a folder.

The most common delay we see is not a failed test, it is a GSPR checklist answered with "complies" and no reference. Reviewers stop reading, and the clock restarts.
GSPR 10

Chemical, physical & biological properties

ISO 10993 biological evaluation, chemical characterization, toxicological risk assessment, residues and degradants.

Biocompatibility evidence
GSPR 11–14

Infection, contamination, sterilization

Sterilization validation, bioburden, residuals, reprocessing validation and packaging integrity for sterile devices.

Validation evidence
GSPR 9, 17

Construction, safety & performance

IEC 60601-1 safety, IEC 60601-1-2 EMC, mechanical and environmental testing to harmonised standards.

Safety & EMC evidence
GSPR 17.2–17.4

Software, usability & connected devices

Software V&V to IEC 62304, usability to IEC 62366-1, cybersecurity documentation to IEC 81001-5-1.

Software evidence
Annex XIV

Clinical evaluation

Inputs for the clinical evaluation report: literature strategy review, equivalence justification gaps, PMCF test endpoints.

Clinical inputs
Annex II

Documentation review

A gap memo against the Annex II structure before the file goes to the notified body, including standard-version currency.

Pre-submission review

One test programme, several markets

Build the evidence once, reuse it in ASEAN.

If you are pursuing both CE and Southeast Asian registrations, the underlying reports are largely the same — only the dossier structure, language and reference approvals change. Sequencing the testing for the stricter file first usually removes duplication.

  • Run to the stricter standard set. MDR-recognised harmonised standards generally satisfy ASEAN expectations; the reverse is not always true.
  • Write reports with both readers in mind. Full data, clause-level results and clear conclusions serve a notified body and an HSA reviewer equally.
  • Keep the standards register current. When an edition is superseded, a gap assessment is cheaper than a re-test — but it has to be written while the team still remembers the design.
  • Plan PMCF and PMS test capacity. Post-market surveillance obligations create recurring testing, not a one-off project.
Laboratory technician preparing samples for biological evaluation
BIOLOGICAL EVALUATION · ANNEX II INPUT

FAQ

MDR questions from SEA manufacturers.

Does a CE certificate cover ASEAN registration?

It helps, it does not replace. Some authorities use reference-agency approvals to expedite review and Vietnam recognises a broad set, but each market still needs its own registration, local representative and often its own labelling.

What changed for testing after MDR replaced the MDD?

The standards largely carried over; the documentation burden did not. MDR adds a fuller GSPR mapping, a clinical evaluation report with a defined literature strategy, PMS and PMCF plans, UDI and, for higher classes, a summary of safety and clinical performance.

How current must the standards be?

Reports must reflect the state of the art, which in practice means the harmonised standards in force. Older editions are generally accepted only with a written gap assessment showing the differences do not affect safety.

Do you act as EU authorised representative?

No. We provide test and evaluation evidence and answer the notified body's technical questions. The authorised representative and notified body are separate appointments held by other parties.

Next step

Planning CE and ASEAN at the same time?

Send the device class, standards claimed and target dates. We map one test programme to both files.