Biological evaluation · ISO 10993

Biocompatibility testing that answers the question reviewers actually ask.

A biological evaluation plan, the in vitro and in vivo tests your contact category requires, and chemical characterization that explains what the device releases — documented to ISO 10993-1:2025 and structured for CSDT, MDR and 510(k) review.

ISO 10993-1:2025GLP in vivo6–10 week core batteryChemical characterization in-house
In short

Biocompatibility testing is a risk-based evaluation, not a fixed menu. ISO 10993-1:2025 asks for chemical and physical characterization first, then in vitro and in vivo tests selected by contact category and duration. For most devices that means cytotoxicity, irritation or sensitization, plus ISO 10993-18 chemical characterization — with implantation or systemic toxicity added for implants and long-term contact.

How the plan is built

Contact category and duration decide the test set.

The 2025 revision of ISO 10993-1 puts more weight on chemical characterization and on justifying why a test is not needed. A plan that simply lists every endpoint in the series reads as unconsidered and invites questions.
ISO 10993 evaluation matrix by contact category and duration
Contact categoryDurationCore endpoints usually requiredTypically added
Surface device
skin, mucosa, breached surface
Limited (≤24 h)
Prolonged (24 h–30 d)
Cytotoxicity; irritation; sensitizationChemical characterization for mucosa or breached-surface contact; clinical use justification
External communicating
indirect blood path, tissue-fluid, blood path
Limited / prolonged / long-termCytotoxicity, irritation, sensitization, plus hemocompatibility for blood contactSystemic toxicity, implantation, chemical characterization, EO residuals where applicable
Implant device
tissue, bone, blood
Prolonged / long-termCytotoxicity, sensitization, implantation with histology, chemical characterizationSystemic toxicity, genotoxicity, carcinogenicity justification, degradation and metal-ion release studies
Resorbable / degradableAllDegradation product characterization, local effects after implantationAbsorption, metabolic pathways, long-term implant endpoints

The matrix is a starting point. Final scope depends on materials, surface area, manufacturing residues, sterilization and the intended clinical exposure.

In vitro & in vivo

Tests we run in-house, with GLP animal facilities on site.

Cell culture and animal work sit in the same quality system as the analytical laboratory, so sample preparation, extraction and results stay traceable across the whole evaluation.

  • In vitro: cytotoxicity (ISO 10993-5), irritation and intracutaneous reactivity, sensitization models, hemolysis and blood interaction.
  • In vivo: implantation with histopathology (ISO 10993-6), systemic toxicity (10993-11), sensitization (10993-10), genotoxicity (10993-3), reproductive and developmental toxicity where justified.
  • Residuals: ethylene oxide and its chlorohydrins, plus sterilization degradation products (ISO 10993-7).
  • Facilities: 28,000 m² animal facility with GLP certification, 600+ instruments, histology and pathology on site.
Scientist handling a 96-well microplate during cytotoxicity testing
CYTOTOXICITY · ISO 10993-5

ISO 10993-18

Chemical characterization: the part that decides how much animal testing you need.

Chemical characterization identifies what a device is made of and what it releases under clinical conditions. Done properly, it can remove whole in vivo endpoints; done superficially, it produces a report that reviewers reject and a re-test bill.

  • Material composition: polymer, metal, ceramic and coating constituents down to trace additives and processing aids.
  • Extractables: controlled extraction at conditions justified against clinical exposure, screened by LC-Q-TOF, GC-MS, ICP-MS and IC.
  • Leachables: measurement of release in clinical-use simulation where the device or application requires it.
  • Toxicological risk assessment: exposure estimate and comparison to tolerable intake, written so a reviewer can follow the logic without asking for the raw calculation.
Scope a characterization study
Gloved technician handling a sterile barrier pouch during packaging testing
SAMPLE PREP · EXTRACTION CONTROL

Deliverables

What lands in your inbox.

Every project yields a signed English report plus the working documents a regulatory reviewer or your EU notified body may request later.
01

Biological evaluation plan

Contact category, materials, endpoints selected and explicitly excluded, with justification and the extraction rationale.

02

Test reports

Signed, accredited reports per method with raw data, instrument traces, photomicrographs and deviations noted.

03

Biological evaluation report

A consolidated conclusion tying chemical data, in vitro and in vivo results into one biological safety statement.

04

Toxicological risk assessment

Exposure-based assessment of identified substances with tolerable intake comparison and open uncertainties stated.

05

CSDT / MDR mapping

Reports indexed to the dossier sections your agent or notified body will open, in English, with an index table.

06

Gap memo

Short letter listing what is still missing for your target market — clinical evidence, labelling, sterilization, software.

FAQ

Biocompatibility questions we answer most often.

Does chemical characterization replace animal testing?

It often reduces it, but it does not automatically replace it. ISO 10993-1:2025 expects characterization first, with in vivo tests added where the chemical data cannot establish biological safety — novel materials, long-term implants, uncertain degradation. Cytotoxicity is still expected in almost every case.

Which extraction conditions do you use?

Per ISO 10993-12, chosen to be at least as severe as clinical use: 37 °C / 24 h for short-term surface contact, 37 °C / 72 h for prolonged contact, and elevated conditions such as 50 °C / 72 h or 70 °C / 24 h where materials allow. Conditions are justified in the plan and stated in the report.

Can we reuse a predicate device's data?

Only where biological equivalence holds: same materials, same manufacturing process, same contact category and duration, same sterilization. A change of resin supplier, mould release agent, colourant or sterilization method usually requires at least partial re-testing.

How much sample is needed?

It scales with exposed surface area, so a dental implant and a surgical drape need very different quantities. After the plan is agreed we issue a sample request for finished devices in final packaging.

Do you support ASEAN submissions specifically?

Yes. Reports are written in CSDT structure with an executive summary of preclinical studies, which is the section HSA, MDA and Thai FDA reviewers open first. See our ASEAN registration page.

Next step

Send your materials list and contact category.

You get a plan that states which endpoints apply, which do not, and why — with dates and price.

Request a biocompatibility plan standard@sitande.com Replies within one working day · English