Biological evaluation
Cytotoxicity, sensitization, irritation, systemic toxicity, implantation, genotoxicity, hemocompatibility, EO residuals — planned against ISO 10993-1:2025.
Biocompatibility detailTesting services
Biological evaluation, electrical safety, EMC, sterilization, packaging and preclinical studies for Class A to D devices — reported in the structure ASEAN, EU and US reviewers expect.
We test the evidence set a medical device submission needs: ISO 10993 biological evaluation, IEC 60601-1 safety and EMC, ISO 11135/11137 sterilization validation, ISO 11607 sterile packaging, chemical characterization to ISO 10993-18, and GLP preclinical studies. Devices come from Singapore, Malaysia, Thailand, Vietnam, Indonesia and the Philippines; reports are issued in English under accredited scope.
Scope
Cytotoxicity, sensitization, irritation, systemic toxicity, implantation, genotoxicity, hemocompatibility, EO residuals — planned against ISO 10993-1:2025.
Biocompatibility detailIEC 60601-1 basic safety and essential performance, IEC 60601-1-2 EMC, collateral and particular standards, environmental and usability testing.
Safety & EMC detailEO, gamma, X-ray, moist heat and VHP validation; sterile barrier systems to ISO 11607-1/-2; shelf-life and transport simulation.
Validation detailMaterial composition, extractables and leachables by Q-TOF, GC-MS and ICP-MS; toxicological risk assessment tied to clinical exposure.
Characterization detailGLP large-animal implantation and functional models, histopathology, degradation and absorption studies for resorbable materials.
Discuss a studyReports mapped to CSDT sections, EU MDR technical documentation and 510(k) summaries, with a gap list before submission.
Regulatory supportStandards
| Category | Core standards | Typical output |
|---|---|---|
| Biological evaluation | ISO 10993-1, -5, -6, -10, -11, -12, -18; ISO/TS 10993-19 | Biological evaluation plan and report; chemical characterization report; toxicological risk assessment |
| Electrical safety | IEC 60601-1, plus collateral standards (60601-1-2, -1-6, -1-8, -1-11, -1-12) and device-specific particulars | Safety test report, abnormal-condition results, risk management inputs |
| EMC | IEC 60601-1-2 (CISPR 11, IEC 61000-4 series) | Emissions and immunity report, test-setup photographs |
| Sterilization | ISO 11135 (EO), ISO 11137 (radiation), ISO 17665 (moist heat), ISO 14937 (VHP), ISO 10993-7 (residuals) | Validation report, half-cycle / bioburden / SAL data, residuals report |
| Packaging | ISO 11607-1, ISO 11607-2, ASTM D4169, ASTM F1929, ASTM F88 | Seal strength, dye penetration, bubble emission, accelerated ageing, transport simulation |
| Software & usability | IEC 62304, IEC 62366-1, IEC 81001-5-1 | Software V&V evidence, usability validation summary, cybersecurity documentation |
| IVD | ISO 23640, CLSI EP series, ISO 18113 | Analytical performance, stability, IFU and labelling verification |
Samples & timeline
Sample quantities are set per standard, not per project, so the number varies by device size and batch structure. The table is the planning baseline we confirm in writing.
FAQ
Three variables drive it: the nature of body contact (surface, external communicating, implant), contact duration (limited, prolonged, long-term), and materials plus manufacturing process. ISO 10993-1:2025 gives the evaluation matrix; active devices add the applicable IEC 60601 collateral standards. We turn those variables into a written test plan before quoting.
It can, but the regulator sees the seams. EO residuals interact with biocompatibility conclusions, packaging validation interacts with shelf life, and an EMC failure can force design changes that invalidate earlier safety data. One quality system usually means fewer repeats.
Yes — analytical performance, stability, labelling and packaging for IVDs; software verification and validation, usability and cybersecurity documentation for connected devices, alongside the hardware safety file.
Device description or brochure, intended use, materials, contact type and duration, sterilization method, target markets and any existing reports. We return standards, sample quantities, dates and price — usually within one working day.
Next step
One reply with the tests you need, the tests you can skip, sample quantities and a fixed price.